Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution
HomeHome > Products > Intelligent Power Solution > Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution
Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution

Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution

Overview Product Description Product Parameters Dimension and Wiring Certifications Company Profile FAQ
Basic Info
Model NO. ATZ2000
Customized Customized
Voltage AC100/220/230/400V
IP Class IP51
Communication Modbus
Operation Temperature -25ºC~55ºC
Operation Humidity ≤90%Rh
Altitude ≤2000m
Average Trouble-Free Operation Time ≥50000h
Power Consumption ≤5W
Frequency 45Hz~65Hz
Accuracy Class Active Power: Class0.5; Reactive Power: Class2
Insulation Class 2
Transport Package Paper Carton + Pallets
Trademark Antin
Origin Hangzhou
HS Code 903033900
Production Capacity 50000 Per Month
Product Description

Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution

Product Parameters

ParameterValue
Applicable gridThree-phase four-wire, three-phase three-wire, single two-wire, three-phase three-wire PT
Working powerVoltage rangeAC/DC85~265V
Power consumption≤5W
InputVoltageRatedAC100V,220V,400V
Overload1.2 times continuous, 2 times (10s)
Power consumption<0.4VA/Phase
Impedance≥200kΩ
CurrentPrimary current1-9999A
Secondary input1A or 5A
Short-time overcurrent20 times the maximum current for 0.5 seconds
Power consumption<0.2VA/Phase
Impedance≥0.1Ω
Frequency45Hz~65Hz
Switching inputDry contact input, photoelectric isolation
OutputSwitching outputRelay output; can set any alarming power, default remote control
Pulse output1 channel electrical energy pulse
Accuracy indexVoltage/current0.5%
Frequency0.2%
Power/power factor1%
Active powerClass0.5S
Reactive powerCLass2
CommunicationBus typeRS485
protocolModbus RTU
Baud rate2400/4800/9600/19200/38400bps
Address range1-247
Bus load64pcs
Communication distance1000m
ParityEVEN/ODD/NONE(default)
Data bits8
Stop bit1
Ethernet porModbus
EnvironmentOperation temperature-25ºC~55ºC
Storage temperature-40ºC~70ºC
Operating humidity≤90%RH, non-condensing, no corrosive air
Storage humidity≤95%RH, non-condensing, no corrosive air
Altitude≤2000m
Installation categoryCATIII
Withstanding voltage capacityAC withstanding voltage 4KV/1min Pulse withstanding voltage 6kV - 1.2µS waveform
IP ClassIP51(Indoors)
Insulation class2
Average trouble-free operation time≥50000h
EMC electromagnetic compatibility testElectrostatic discharge immunity testGB/T 17626.2-2006:test level 4, test voltage 8kV
RF electromagnetic field immunity testGB/T 17626.3-2006:test level 3, test field strength of 10V / m
Fast transient pulse group testGB/T 17626.4-2008:test level 2, current voltage 1kV, other 500V
Surge (shock) immunity testGB/T 17626.5-2008:test level 4, test voltage 4kV
RF field induction conducted harassment immunity testGB/T 17626.6-2008:test level 3, test field strength of 10V / m
Voltage transients, short interruptions and voltage changes in the immunity testGB/T 17626.11-2008:current and voltage test error qualified
Oscillation wave immunity testGB/T 17626.12-1998:Class B ITE test, qualified
Conformity to StandardsGBT22264.1-2008 Mounted digital display electrical measuring instrument Part 1: Definition and general requirements
GBT22264.7-2008 Mounted digital display electrical measuring instrument Part 7: Special requirements for multifunctional instruments
GBT22264.8-2009 Mounted digital display electrical measuring instrument Part 8:Recommended test methods

Dimension and Wiring

Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution

Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution

Certifications

Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution

Company Profile

Antin Multi-Circuit Submeter, Pad Mounted Metering Solution, Panel Mounted Metering Solution

FAQ